Customize
Three questions are enough: the size of the opening, what passes through it, and the conditions on each side. The rest is calculated.
- Recommended strip
- –
- Overlap
- –
- Number of strips
- –
- Length per strip
- –
- Total length
- –
- Fixing
- –
Selection rules
Indicative values
Width and thickness by height
| Opening height | Strip | Reference |
|---|---|---|
| Up to 2.5 m | 200 x 2 mm | LT200x2 |
| 2.5 to 3.5 m | 300 x 3 mm | LT300x3 |
| 3.5 to 4.5 m | 400 x 3 mm | LT400x3 |
| Over 4.5 m | 400 x 4 mm | LT400x4 |
The taller the opening, the wider and thicker the strip must be to hang straight and resist the wind.
Overlap by traffic
| Traffic | Overlap |
|---|---|
| Pedestrians, indoor | 30 % |
| Pallet trucks, hand carts | 50 % |
| Forklifts, draughts | 66 % |
| Cold room | 66 % and more |
The overlap is the part of each strip covered by the next one. The higher it is, the better the seal.
Formulation by environment
- Standard transparent for temperate and chilled environments.
- Low temperature (LGF200x2) for sub-zero cold rooms: the strip stays flexible in the cold.
- Yellow citronella anti-insect (LT300x2AN-IC) for exterior accesses of food areas.
- Magnetic bands (LTMAG3X2,5) when the strips must close against each other.
- Colours and opaque to signal a passage or screen off an area.
These rules give a first order of magnitude. The Tunitaly Flex quote confirms the reference, the overlap and the fixing after studying your opening.